To calculate the space necessary for the installation of the equipment with
respect to its length, in addition to the measurements indicated in the table,
280mm (minimum) must be added to open the access door to the distributor
drain.
Electrical Consumption
In order to install, we should take into consideration the total consumption
of the installation, including the consumption of the installed hoses and
applicators.
Before connecting, make sure that the voltage that is being connected to
the melter/applicator is the correct one appearing on the equipment’s
characteristics plate.
Connect the machine and check to see if it is well grounded.
Warning:
Risk of electrocution. Even when the equipment is turned off,
voltage remains in the intake terminals, which may be dangerous during
internal equipment manipulations.
Install a power switch for disconnecting the melter/applicator equipment from
the electrical network. It must be protected against overload and short circuits
by circuit breaker and install appropriate personal protection leads to mass by
differential switch.
Consumption figures, according to melter/applicator and output configuration,
are included in the table in the section ‘Electrical power connection’.
E
A
C
D
B
Summary of Contents for Micron PUR LC
Page 1: ...ADHESIVE MELTER MICRON PUR LC MC INSTRUCTIONS MANUAL MA 5184 GBR 010920 GLUING SOLUTIONS ...
Page 20: ...This page is intentionally left blank MELER GLUING SOLUTIONS 2 8 INTRODUCTION ...
Page 34: ...MELER GLUING SOLUTIONS INSTALLATION 3 14 This page is intentionally left blank ...
Page 84: ...MELER GLUING SOLUTIONS 5 10 MAINTENANCE Esta página no contiene texto ...
Page 90: ...MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Page 94: ...MELER GLUING SOLUTIONS 9 2 SPARE PARTS LIST This page is intentionally left blank ...