FOCKE MELER GLUING SOLUTIONS
6-10
TROUBLESHOOTING
Note
Hose 1
Hose 2
Hose 3
Hose 4
(1)
CN10 / M3
CN10 / M4
CN11 / M5
CN11 / M6
(2)
F06
F07
F08
F09
(3)
CN10 / M3 / DL7
CN10 / M4 / DL9
CN11/ M5 /DL11
CN11/ M6 /DL13
(4)
DL7
DL9
DL11
DL13
(5)
CN4
CN5
CN6
CN7
Micron with 2 geared motor
Causes
Checking
Comments
Actions
Applicator damaged.
Replace the applicator by
another one that works.
Change applicator channel.
Change applicator.
Hose damaged.
Replace the hose by
another one that works.
Change hose channel.
Change hose.
Pins and wiring
damaged.
Check voltage between
board and applicator-
output connector (with the
hose plugged).
CN
(*)
connector (black wire-neutral
and red wire-applicator P
(*)
).
( 1 )
Change connectors.
Ribbon cable wrong
placed.
Observe ribbon cable
connection.
Ribbon cable correct if red LED light
on (DL15).
Put ribbon cable
correctly.
Power board fuse
damaged.
Verify fuse continuity.
( 2 )
Check continuity with the unit turned
off.
Change fuse.
Power board
damaged.
Check voltage at the board
output (with the hose
plugged).
CN
(*)
board connector (black wire-
neutral and red wire-applicator
P
(*)
). Fuse shows continuity. DL
(*)
LED light remains on.
( 3 )
Change power board.
Applicator
Applicator does not heat
Causes
Checking
Comments
Actions
Power board
damaged.
Check power board.
DL
(*)
LED green indicator is
continuously off.
( 4 )
Change power board.
Control board
damaged.
--
DL
(*)
LED green indicator is
continuously on.
( 4 )
Change control board.
Applicator does not stop heating
Causes
Checking
Comments
Actions
Applicator temperature
sensor malfunction.
Replace the applicator by
another one that works.
Change applicator channel.
Change applicator.
Sensor wiring.
Check sensor board and
applicator connector.
CN
(*)
sensor board connector (black
and blue wire).
( 5 )
Change connector.
Sensor board
malfunction.
Last failure option.
Check first sensors, connections and
wirings.
Change the sensor board.
Temperature fluctuations in applicator
Summary of Contents for Micron 5
Page 1: ...ADHESIVE MELTER MICRON GEAR SERIES INSTRUCTIONS MANUAL MA 5079 ENG 200718 GLUING SOLUTIONS ...
Page 10: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Page 36: ...FOCKE MELER GLUING SOLUTIONS INSTALLATION 3 14 This page is intentionally left blank ...
Page 70: ...FOCKE MELER GLUING SOLUTIONS 4 34 MELTER OPERATION This page is intentionally left blank ...
Page 80: ...FOCKE MELER GLUING SOLUTIONS 5 10 MAINTENANCE This page is intentionally left blank ...
Page 94: ...FOCKE MELER GLUING SOLUTIONS 6 14 TROUBLESHOOTING This page is intentionally left blank ...
Page 102: ...FOCKE MELER GLUING SOLUTIONS 8 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Page 106: ...FOCKE MELER GLUING SOLUTIONS 10 2 SPARE PARTS LIST This page is intentionally left blank ...