INSTALLATION
3-9
MA-5079-ENG
MICRON GEAR ADHESIVE MELTER
• Output disabled_
disabled input signal for each hose-applicator output
via a non-voltage contact. With a closed contact, the output remains
activated (output on); with an open contact, it is deactivated (output off).
• Motor start up_
for each pump installed, the motor start up may be
controlled by closing an external non-voltage contact.
• Motor speed set point_
for each pump installed, the rotational speed of
the motor (and therefore, the pump) may be controlled by means of a 0
to 10V DC external signal.
• Failures
output in pump control card_
output from a non-voltage
contact that communicates normally to a warning light beacon the
failure from the pump control card.
Warning:
Risk of electric shock. Carelessness may cause injuries or death.
If any of these signals are to be connected, open the electrical cabinet for
greater convenience while carrying out this task. To do this, follow the steps
outlined below:
1. Remove the electrical cabinet casing following the instructions given
in the maintenance section ‘Removal and replacement of casing
elements’.
2. Open the electrical cabinet side panel by loosening the screw indicated.
Use Allen wrench 3.
Temperature ok
1. If only this signal will be connected, use a 0.5 mm
2
two-wire cable.
Install an electrical wall bushing Pg13.5 next to the electrical supply
input.
2. Thread the power cord (max. Ø12.5mm) through the electrical wall
bushing Pg13.5 and fasten it to the inside anchor, making sure that the
cord reaches the power card connector.
Summary of Contents for Micron 5
Page 1: ...ADHESIVE MELTER MICRON GEAR SERIES INSTRUCTIONS MANUAL MA 5079 ENG 200718 GLUING SOLUTIONS ...
Page 10: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Page 36: ...FOCKE MELER GLUING SOLUTIONS INSTALLATION 3 14 This page is intentionally left blank ...
Page 70: ...FOCKE MELER GLUING SOLUTIONS 4 34 MELTER OPERATION This page is intentionally left blank ...
Page 80: ...FOCKE MELER GLUING SOLUTIONS 5 10 MAINTENANCE This page is intentionally left blank ...
Page 94: ...FOCKE MELER GLUING SOLUTIONS 6 14 TROUBLESHOOTING This page is intentionally left blank ...
Page 102: ...FOCKE MELER GLUING SOLUTIONS 8 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Page 106: ...FOCKE MELER GLUING SOLUTIONS 10 2 SPARE PARTS LIST This page is intentionally left blank ...