MELTER OPERATION
4-7
MA-5079-ENG
MICRON GEAR ADHESIVE MELTER
Standby function does not generate any alarm.
If a temperature sensor is broken, the system heats all the elements except
the one where the failure is located.
In case of overheating the system cuts off inmediately the damaged element.
After three minutes if the failure continues all the system will be shut down.
After repairing the failure the system starts heating normally.
Hot-melt level display (optional)
If the equipment is fitted with a level detector, and the hot-melt level drops
below the programmed level (capacitive detector) or 1/3 of the tank capacity
(float type detector), a signal is sent to the melter control which launches the
following actions:
1. On-screen display (if this function is activated).
2. Closure of one voltage-free output contact. The user will install the
required device (acoustic warning device, lamp or PLC input).
Simply refill the tank and wait until the adhesive is sufficiently melted for the
detector to provide a reading of the correct level.
Display and adjustment of the working speed
The pump rotation speed (in revolutions per minute) is shown on the
display for each pump control card on the equipment. These revolutions
may be adjusted by using the up/down arrow keys (pumping speed, internal
reference), through a voltage signal from the main machine or by modifying
the full scale (pumping speed, external reference). The pump rotation speed
must be adjusted to the requirements of the application.
Warning
: Although rotation speeds can be selected between 0 and 100 rpm
it is not advisable to operate at speeds of less than 10 rpm (the flow may
become inconstant depending on the motor load) or greater than 80 rpm
(pump operating at maximum revolutions).
Note:
for further information on adjusting working speeds, see the section
‘Modes of operation’.
Summary of Contents for Micron 5
Page 1: ...ADHESIVE MELTER MICRON GEAR SERIES INSTRUCTIONS MANUAL MA 5079 ENG 200718 GLUING SOLUTIONS ...
Page 10: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Page 36: ...FOCKE MELER GLUING SOLUTIONS INSTALLATION 3 14 This page is intentionally left blank ...
Page 70: ...FOCKE MELER GLUING SOLUTIONS 4 34 MELTER OPERATION This page is intentionally left blank ...
Page 80: ...FOCKE MELER GLUING SOLUTIONS 5 10 MAINTENANCE This page is intentionally left blank ...
Page 94: ...FOCKE MELER GLUING SOLUTIONS 6 14 TROUBLESHOOTING This page is intentionally left blank ...
Page 102: ...FOCKE MELER GLUING SOLUTIONS 8 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Page 106: ...FOCKE MELER GLUING SOLUTIONS 10 2 SPARE PARTS LIST This page is intentionally left blank ...