MAINTENANCE
5-5
MA-5079-ENG
MICRON GEAR ADHESIVE MELTER
7. Replace the assembly inside the distributor and fasten it clockwise.
Tighten the purge screw clockwise with a flat blade screwdriver.
8. Continue working as usual.
Cleaning the tank
The hot-melt tank must be cleaned on occasion to maintain its fusion and
anti-adherence properties. The tank is covered on the inside with PTFE and
inclined enough to aid unloading the hot-melt and to avoid it from being
retained inside when consequential burning occurs.
Furthermore, when adhesives are mixed, reactions may occur between them,
causing a degeneration and thus problems in unloading in the direction of the
pump.
Therefore, it is recommended to clean the deposit every time that:
• A change is made to a different type of hot-melt.
• Too much burnt material is generated in its interior.
Changing adhesive type
1. Use up as much of the adhesive as possible.
If it is necessary to unload the adhesive without having used it up as
much as possible, follow the instructions in the section ‘Emptying the
tank’.
2. Clean the remains of hot-melt adhesive on the inside of the tank.
Warning:
Use appropriate protective equipment for high temperatures.
3. Add the appropriate type and quantity of the new adhesive, wait for it
to melt and pump at least one full tank through the system (hoses and
applicators).
Cleaning burnt adhesive
1. Empty the tank directly (see the section ‘Emptying the tank’) to prevent
the burnt material from passing through the pump circuit.
2. Clean the adhesive remains and burnt material inside the tank. Do not
use sharp objects that might damage the inside coating.
Warning:
Use appropriate protective equipment for high temperatures.
3. Add the appropriate type and quantity of adhesive and wait for it to melt.
Summary of Contents for Micron 5
Page 1: ...ADHESIVE MELTER MICRON GEAR SERIES INSTRUCTIONS MANUAL MA 5079 ENG 200718 GLUING SOLUTIONS ...
Page 10: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Page 36: ...FOCKE MELER GLUING SOLUTIONS INSTALLATION 3 14 This page is intentionally left blank ...
Page 70: ...FOCKE MELER GLUING SOLUTIONS 4 34 MELTER OPERATION This page is intentionally left blank ...
Page 80: ...FOCKE MELER GLUING SOLUTIONS 5 10 MAINTENANCE This page is intentionally left blank ...
Page 94: ...FOCKE MELER GLUING SOLUTIONS 6 14 TROUBLESHOOTING This page is intentionally left blank ...
Page 102: ...FOCKE MELER GLUING SOLUTIONS 8 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Page 106: ...FOCKE MELER GLUING SOLUTIONS 10 2 SPARE PARTS LIST This page is intentionally left blank ...