![Meler Micron 5 Instruction Manual Download Page 67](http://html1.mh-extra.com/html/meler/micron-5/micron-5_instruction-manual_1767103067.webp)
MELTER OPERATION
4-31
MA-5079-ENG
MICRON GEAR ADHESIVE MELTER
Programming speed ramp
To access this menu and program the different points corresponding to the voltage-
speed ratio, you must select external reference (‘ref ext’ LED is illuminated) and
press the right arrow key. Then the following message is displayed:
The IN LED to the position
ON
and the OUT LED to the position
OFF, 1 000,
NOT EDITABLE;
press the right arrow to go to the next point:
The IN LED to the position
OFF
and the OUT LED to the position
ON, 1 XXX,
which means that the output speed is being programmed for point 1 (when the
input voltage is 0 V); with the up/down arrow keys the value may be modified,
within a range from 000 to MAXIMUM RPM; press the right arrow key to go to
the next point:
The IN LED to the position
ON
and the OUT LED to the position
OFF, 2 XXX
,
which means that the input voltage value is being programmed for point 2; with
the up/down arrow keys the value may be modified, within a range from 00.0 to
10.0 (to one decimal place); press the right arrow key to go to the next point:
The IN LED to the position
OFF
and the OUT LED to the position
ON, 2 XXX,
which means that the output speed value is being programmed for point 2;
with the up/down arrow keys the value may be modified, within a range from
000 to MAXIMUM RPM; press the right arrow key to go to the next point:
The IN LED to the position
ON
and the OUT LED to the position
OFF, 3 XXX
,
which means that the input voltage value is being programmed for point 3; with
the up/down arrow keys the value may be modified, within a range from 00.0 to
10.0 (to one decimal place); press the right arrow key to go to the next point:
The IN LED to the position
OFF
and the OUT LED to the position
ON, 3 XXX,
which means that the output speed value is being programmed for point 3;
with the up/down arrow keys the value may be modified, within a range from
000 to MAXIMUM RPM; press the right arrow key to go to the next point:
The IN LED to the position
ON
and the OUT LED to the position
OFF, 4 XXX,
which means that the input voltage value is being programmed for point 4; with
the up/down arrow keys the value may be modified, within a range from 00.0 to
10.0 (to one decimal place); press the right arrow key to go to the next point:
The IN LED to the position
OFF
and the OUT LED to the position
ON, 4 XXX,
which means that the output speed value is being programmed for point 4;
with the up/down arrow keys the value may be modified, within a range from
000 to MAXIMUM RPM; press the right arrow key to go to the next point:
The IN LED to the position
ON
and the OUT LED to the position
OFF, 5 100,
NOT EDITABLE; press the right arrow key to go to the following message:
The IN LED to the position
OFF
and the OUT LED to the position
ON, 5 XXX,
which means that the speed value is being programmed for point 5; with the
up/down arrow keys the value may be modified, within a range from 000 to
MAXIMUM RPM; press the right arrow key to exit the menu.
Press the right arrow key to return to the menu, and the initial message is
displayed: The IN LED to the position
ON
and the OUT LED to the position
ON,
1 000.
To exit this menu, the equipment must be turned off and started up using the
control card ON/OFF button.
To save the newly entered data, use the right and left arrow keys to go forward
or backward in the menu: if any field has been modified using the up/down
arrow keys, and the ON/ OFF button is pressed to turn the equipment off, the
data will not be saved.
Summary of Contents for Micron 5
Page 1: ...ADHESIVE MELTER MICRON GEAR SERIES INSTRUCTIONS MANUAL MA 5079 ENG 200718 GLUING SOLUTIONS ...
Page 10: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Page 36: ...FOCKE MELER GLUING SOLUTIONS INSTALLATION 3 14 This page is intentionally left blank ...
Page 70: ...FOCKE MELER GLUING SOLUTIONS 4 34 MELTER OPERATION This page is intentionally left blank ...
Page 80: ...FOCKE MELER GLUING SOLUTIONS 5 10 MAINTENANCE This page is intentionally left blank ...
Page 94: ...FOCKE MELER GLUING SOLUTIONS 6 14 TROUBLESHOOTING This page is intentionally left blank ...
Page 102: ...FOCKE MELER GLUING SOLUTIONS 8 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Page 106: ...FOCKE MELER GLUING SOLUTIONS 10 2 SPARE PARTS LIST This page is intentionally left blank ...