![Meler Micron 5 Instruction Manual Download Page 56](http://html1.mh-extra.com/html/meler/micron-5/micron-5_instruction-manual_1767103056.webp)
FOCKE MELER GLUING SOLUTIONS
4-20
MELTER OPERATION
4. Press the button with the clock symbol once again.
The status will alternate each time you press the button.
5. Pressing either the left or the right arrow button will exit this program
and return to the tank temperature display.
Special function buttons
The simplicity of programming ‘micron’ series melters/applicators reduces
the use of the special function buttons to only the standby function.
This manual function allows you to alternate between the operational mode
and the standby mode. Using the standby function during periods of melter/
applicator inactivity helps save energy and allows the heated elements
to return quickly to their set point temperatures once you return to the
operational mode.
When the standby function is activated, the set point temperature for all the
heated components is lowered to a certain value, according to the programmed
parameter (see ‘Programming melter/applicator equipment parameters’).
For example, if the tank set point temperature is 160 °C and the standby
temperature is programmed as 30 (30%), when you press the standby function
button, the tank set point temperature will drop to 112 °C (70% of 160 °C).
The three means for activating the standby function available with ‘micron’
melters/applicators have the following priority protocols:
1° manual standby function button
2° standby function external signal
3° standby function activation/deactivation programming
Therefore, if the function is activated by any of the three means, it may always
be deactivated using the manual button. On the other hand, if it was activated
using the manual button, it may not be deactivated by either of the other two
means. The weekly programming may not deactivate a standby function that
has been activated by either of other two means.
The following criteria are suggested for standby function use:
- If the period of inactivity is less than 2 hours, allow the melter
applicator equipment to heat as normal.
- If the period of inactivity is more than 2 hours and less than 4 hours,
use the standby function.
- If the period of inactivity is over 4 hours, use one of the following two
options: turn off the equipment if you do not plan on using it for the
rest of the day or keep the standby function on if you plan on using the
equipment during that same day.
Summary of Contents for Micron 5
Page 1: ...ADHESIVE MELTER MICRON GEAR SERIES INSTRUCTIONS MANUAL MA 5079 ENG 200718 GLUING SOLUTIONS ...
Page 10: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Page 36: ...FOCKE MELER GLUING SOLUTIONS INSTALLATION 3 14 This page is intentionally left blank ...
Page 70: ...FOCKE MELER GLUING SOLUTIONS 4 34 MELTER OPERATION This page is intentionally left blank ...
Page 80: ...FOCKE MELER GLUING SOLUTIONS 5 10 MAINTENANCE This page is intentionally left blank ...
Page 94: ...FOCKE MELER GLUING SOLUTIONS 6 14 TROUBLESHOOTING This page is intentionally left blank ...
Page 102: ...FOCKE MELER GLUING SOLUTIONS 8 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Page 106: ...FOCKE MELER GLUING SOLUTIONS 10 2 SPARE PARTS LIST This page is intentionally left blank ...