![Meler Micron 5 Instruction Manual Download Page 73](http://html1.mh-extra.com/html/meler/micron-5/micron-5_instruction-manual_1767103073.webp)
MAINTENANCE
5-3
MA-5079-ENG
MICRON GEAR ADHESIVE MELTER
System depressurisation
Even with the motor turned off, residual pressure may exist in the circuit. This
must be kept in mind when performing any operation on the hydraulic circuit.
Before disconnecting any hydraulic element or opening any distributor outlet,
it is necessary to perform the following steps:
1. Turn off the machine switch on the door of the electrical cabinet.
2. Operate the purge valve housed in each distributor to free any residual
pressure from the circuit. Adhesive residues fall down by the laterally
positioned chute for this purpose.
3. Purge all applicators that have been used either manually or with the
corresponding program command.
Access to the interior of the equipment
Access to distributor
To access the distributor where both the bypass valve pressure regulator and
the purge-filter assembly are located it is necessary to open the casing as
indicated. To do this, loosen the quarter turn screw that keeps the access door in
the closed position (A).
Access to pump gear- motor
To access the pump- gear motor assembly, it is necessary to remove the electrical
cabinet from its location together with the portion of the chassis that lies
underneath. To do this, loosen the quarter turn screw that keeps the equipment in
the closed position (B) and slide it on the guides.
Next, open the access door to the distributor (A) and remove the front casing by
releasing the screws as shown (C).
To access the interior of the equipment it is not necessary to open the
electrical cabinet door.
A
C
B
C
Summary of Contents for Micron 5
Page 1: ...ADHESIVE MELTER MICRON GEAR SERIES INSTRUCTIONS MANUAL MA 5079 ENG 200718 GLUING SOLUTIONS ...
Page 10: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Page 36: ...FOCKE MELER GLUING SOLUTIONS INSTALLATION 3 14 This page is intentionally left blank ...
Page 70: ...FOCKE MELER GLUING SOLUTIONS 4 34 MELTER OPERATION This page is intentionally left blank ...
Page 80: ...FOCKE MELER GLUING SOLUTIONS 5 10 MAINTENANCE This page is intentionally left blank ...
Page 94: ...FOCKE MELER GLUING SOLUTIONS 6 14 TROUBLESHOOTING This page is intentionally left blank ...
Page 102: ...FOCKE MELER GLUING SOLUTIONS 8 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Page 106: ...FOCKE MELER GLUING SOLUTIONS 10 2 SPARE PARTS LIST This page is intentionally left blank ...