MELTER OPERATION
4-29
MA-5079-ENG
MICRON GEAR ADHESIVE MELTER
Displaying alarms and reset function
Maximum rpm alarm
This alarm will be triggered when the motor rotates at a speed exceeding the
MAXIMUM RPM ALARM value for the period established in the MAXIMUM RPM
ALARM TIME field.
• When this alarm is triggered, an ‘E.H.’ error is shown on the control
card.
• To reset this error, you must turn off and start up the control card with
its ON/OFF button.
Minimum rpm alarm
This alarm will be triggered when the motor rotates at a speed that is below
the MINIMUM RPM ALARM for the period established in the MINIMUM RPM
ALARM TIME field.
• When this alarm is triggered, an ‘E.L.’ error is shown on the control
card.
• To reset this error, you must turn off and start up the control card with
its ON/OFF button.
Variator alarm
This alarm is triggered when the control card input is activated by a variator
error signal.
• When this alarm is triggered, an ‘E.U.’ error is shown on the control
card.
• The error message will be maintained while the variator error input
(E5) remains active. As soon as this input is deactivated the alarm will
be reset.
Note:
In the event that a RPM alarm and a variator ERROR alarm should
coincide, alternating messages will appear on the display.
Summary of Contents for Micron 5
Page 1: ...ADHESIVE MELTER MICRON GEAR SERIES INSTRUCTIONS MANUAL MA 5079 ENG 200718 GLUING SOLUTIONS ...
Page 10: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Page 36: ...FOCKE MELER GLUING SOLUTIONS INSTALLATION 3 14 This page is intentionally left blank ...
Page 70: ...FOCKE MELER GLUING SOLUTIONS 4 34 MELTER OPERATION This page is intentionally left blank ...
Page 80: ...FOCKE MELER GLUING SOLUTIONS 5 10 MAINTENANCE This page is intentionally left blank ...
Page 94: ...FOCKE MELER GLUING SOLUTIONS 6 14 TROUBLESHOOTING This page is intentionally left blank ...
Page 102: ...FOCKE MELER GLUING SOLUTIONS 8 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Page 106: ...FOCKE MELER GLUING SOLUTIONS 10 2 SPARE PARTS LIST This page is intentionally left blank ...