INSTALLATION
3-3
MA-5079-ENG
MICRON GEAR ADHESIVE MELTER
Compressed air
As an option, a pneumatically activated by-pass valve or an air drying system
may be installed. If these are added to the system, a dry, unlubricated
compressed air network must be available, with a maximum pressure of 6 bar.
The by-pass valve consumes next to no air, given that this is a pressurized
closed circuit. In the case of the air dryer, this depends on the frequency of
application, and therefore consumption must be estimated for each case.
Other factors
While installing these melters, other practical considerations should be kept
in mind:
• Keep the load opening accessible for comfortable melter filling.
• Position the melter equipment in such a way that you can easily see the
front panel display where temperatures and possible alarm signals are
shown.
• As much as possible, try to avoid unnecessarily long hoses that result
in elevated electrical energy consumption levels and pressure drops.
• Do not install the melter equipment beside powerful heat or cooling
sources that may have distortional effects upon its operation.
• Avoid melter vibrations.
• Make sure that the melter maintenance areas (filter, purging valve,
tank interior, etc.) are easily accessible.
Unpacking
Before proceeding with the installation of the melter, it should be removed
from its location on a pallet and examined in order to detect any possible
breakage or deterioration. Communicate any defect, even to the outer packing
materials, to your Meler Representative or to the Main Office.
Contents
The equipment packing materials may contain accessories that form part of
the same order. If this is not the case, the following are the standard
components that accompany the melter:
• Instruction manual.
• Quick start guide.
• Guarantee card.
• Connector for external I/O (included on the power card).
Summary of Contents for Micron 5
Page 1: ...ADHESIVE MELTER MICRON GEAR SERIES INSTRUCTIONS MANUAL MA 5079 ENG 200718 GLUING SOLUTIONS ...
Page 10: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Page 36: ...FOCKE MELER GLUING SOLUTIONS INSTALLATION 3 14 This page is intentionally left blank ...
Page 70: ...FOCKE MELER GLUING SOLUTIONS 4 34 MELTER OPERATION This page is intentionally left blank ...
Page 80: ...FOCKE MELER GLUING SOLUTIONS 5 10 MAINTENANCE This page is intentionally left blank ...
Page 94: ...FOCKE MELER GLUING SOLUTIONS 6 14 TROUBLESHOOTING This page is intentionally left blank ...
Page 102: ...FOCKE MELER GLUING SOLUTIONS 8 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Page 106: ...FOCKE MELER GLUING SOLUTIONS 10 2 SPARE PARTS LIST This page is intentionally left blank ...