MA-5162-ENG
PISTON ADHESIVE MELTER
MAINTENANCE
5-7
Safety Thermostat
If there is an error in the resettable thermostat. Dismantle the tank casing
with the cover and slide the electrical cabinet along. When you can see the
thermostat, press the button indicated to reset it.
Warning:
Use appropriate protective equipment for high temperatures.
Remove the equipment from its base
For more thorough equipment maintenance, it is necessary to remove it from
its present location to be able to perform operations more comfortably and
with greater accessibility.
To do this, the equipment should be removed from its base following these
indications:
1. Turn off the machine switch on the door of the electrical cabinet next to
the pressure regulator.
2. Depressurise the system.
3. Disconnect the hoses connected to the distributor outputs both
electrically and hydraulically.
4. Disconnect the input power supply and ground connection.
5. Raise the machine to extract it from the base.
Summary of Contents for Micron + 10
Page 10: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Page 38: ...FOCKE MELER GLUING SOLUTIONS INSTALLATION 3 16 This page is intentionally left blank ...
Page 74: ...FOCKE MELER GLUING SOLUTIONS 4 36 MELTER OPERATION This page is intentionally left blank ...
Page 84: ...FOCKE MELER GLUING SOLUTIONS 5 10 MAINTENANCE This page is intentionally left blank ...
Page 91: ...MA 5162 ENG MICRON PISTON ADHESIVE MELTER ELECTRICAL DRAWINGS 7 1 7 ELECTRICAL DRAWINGS ...
Page 92: ...FOCKE MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Page 102: ...FOCKE MELER GLUING SOLUTIONS 8 10 PNEUMATIC DIAGRAM This page is intentionally left blank ...
Page 104: ...FOCKE MELER GLUING SOLUTIONS 9 2 SPARE PARTS LIST This page is intentionally left blank ...