MELTER OPERATION
Calculating the adhesive density
The calculation must be done when:
• The unit is programmed for its first use.
• The type of adhesive is changed.
Important:
During the calculation, the unit must be at the same pressure and
temperate at which the system calibration was done.
Warning:
Always wear gloves and safety goggles. Burn risk.
1. Prepare a container and a scale (tared with the weight of the container).
The unit must be ready to fire freely through an applicator.
2. Press ‘Play’ in ‘Automatic density calculation’. A 10 second countdown
begins to get ready for application. Once this time has passed, an alarm
sounds and adhesive will be applied freely into the container for 60
seconds.
3. Another alarm will sound after 60 seconds. Stop the adhesive application,
weigh it, and enter the value in the ‘Weight’ section.
4. The unit automatically calculates the density and updates the value in the
‘Density’ section.
5. Optionally, you can directly enter the adhesive density value at the
working temperature manually (value between 0.8 and 1 gr/cm3).
6. Press ‘Save’ once the process is completed.
PISTÓN
HMI
: S02001101 v1.1.2
TC
: S02200100 v1.0.84
IO FM : XXXXXXXXX vx.x.x
70
bar
Play
st/10h
g
g/cm3
59s
Play
7cc Pump
Flowmeter
Product Configuration
Pressure
Calibration
Adjustment
Density calculation
Weight
Density
3
2
6
!
4
Product configuration
Once the calibration is done you can now work accurately with the flowmeter.
Before and during the job you can change a set of parameters that are
configured from the flowmeter settings menu.
You can configure up to 5 different products. To edit them, press ‘Product
configuration’.
PISTÓN
HMI
: S02001101 v1.1.2
TC
: S02200100 v1.0.84
IO FM : XXXXXXXXX vx.x.x
70
bar
Play
st/10h
g
g/cm3
59s
Play
7cc Pump
Flowmeter
Product Configuration
Pressure
Calibration
Adjustment
Density calculation
Weight
Density
Summary of Contents for Micron + 10
Page 10: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Page 38: ...FOCKE MELER GLUING SOLUTIONS INSTALLATION 3 16 This page is intentionally left blank ...
Page 74: ...FOCKE MELER GLUING SOLUTIONS 4 36 MELTER OPERATION This page is intentionally left blank ...
Page 84: ...FOCKE MELER GLUING SOLUTIONS 5 10 MAINTENANCE This page is intentionally left blank ...
Page 91: ...MA 5162 ENG MICRON PISTON ADHESIVE MELTER ELECTRICAL DRAWINGS 7 1 7 ELECTRICAL DRAWINGS ...
Page 92: ...FOCKE MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Page 102: ...FOCKE MELER GLUING SOLUTIONS 8 10 PNEUMATIC DIAGRAM This page is intentionally left blank ...
Page 104: ...FOCKE MELER GLUING SOLUTIONS 9 2 SPARE PARTS LIST This page is intentionally left blank ...