FOCKE MELER GLUING SOLUTIONS
2-6
INTRODUCTION
series range
5
series
Tank capacity _
5: 5kg • 10: 10kg • 20: 20kg • 35: 35kg
4 M01 200 BP
7
400N
Electrical outputs_
2 • 4 • 6
Sensor type _
M01: Pt100 • N01: Ni120 • HB01: Pt100 Bühnen • R01: NTC-R
Maximum temperature_
200: 200°C • 230: 230°C
Pump size _
7: 7cc/stroke • 19: 19 cc/stroke
Power supply _
400N: 3N~400V 50/60Hz + PE • 400: 3~400V 50/60Hz + PE •
230: 3 ~ 200/240V 50/60Hz + PE • 480: 3~480V 50/60Hz + PE
/
LD2 B
VP MB
Lid _
(in blank): Standard lid • CG: With granulate feeder installed
Level detector _
(in blank): Prepared for floating detector •
LD2: With capacitive detector installed
Pressure proportional system_
(in blank): Not prepared •
VP: Prepared
Communications _
(in blank): No communications •
MB: ModBus • PB: ProfiBus • PN: ProfiNet •
EN: Ethernet-IP • W: Wifi
-
Pump type _
BP: Piston
Flowmeter _
(in blank): Without flowmeter •
F: With flowmeter
Light tower _
(in blank): Not prepared • B: Prepared
Starbi integration _
(in blank): Not integrated •
S: Starbi integrated (2 channels)
E
Melter Control
(in blank): Internal •
E: Prepared for external control
F
B
Bluetooth _
(in blank): Without •
B: With Bluetooth
Certifications _
(in blank): CE •
UL: UL
Notes
• All versions are prepared for floating detector.
• When the automatic feeder is included, the suction tube and hose must be ordered separately.
• The tower light must be ordered separately.
• The foating detector must be ordered separately.
• The VP system must be ordered separately.
• External control must be ordered separately.
• For 3~400V 50/60Hz + PE & 3~480V 50/60Hz + PE, the transformer base is included.
Summary of Contents for Micron + 10
Page 10: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Page 38: ...FOCKE MELER GLUING SOLUTIONS INSTALLATION 3 16 This page is intentionally left blank ...
Page 74: ...FOCKE MELER GLUING SOLUTIONS 4 36 MELTER OPERATION This page is intentionally left blank ...
Page 84: ...FOCKE MELER GLUING SOLUTIONS 5 10 MAINTENANCE This page is intentionally left blank ...
Page 91: ...MA 5162 ENG MICRON PISTON ADHESIVE MELTER ELECTRICAL DRAWINGS 7 1 7 ELECTRICAL DRAWINGS ...
Page 92: ...FOCKE MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Page 102: ...FOCKE MELER GLUING SOLUTIONS 8 10 PNEUMATIC DIAGRAM This page is intentionally left blank ...