Technician settings (Cont’)
Tel: (856) 2882882
Tel: +972-3-9626462
Fax: +972-3-9626620
support@meitavtec
.
com
PYROCON19
Owner’s manual & Technician Settings
Pg. 16
P11 – Master/Slave
Press the [SELECT] and [+] buttons simultaneously.
“P11” will appear on display.
Use the [+] and [-] buttons to select between:
- “
Π
A” - Master (When using one PYROCON19 or when controlling other
PYROCON19 devices connected to A,B as slaves) - default
- “SL” - Slave (controlled by another PYROCON19 connected to A2,B2)
Slave
Master
P12 – Controller’s MAC Address
Press the [SELECT] and [+] buttons simultaneously.
“P12” will appear on display.
Use the [+] and [-] buttons to set the controller’s MAC address:
- For controller set by P11 as Master –
Address range for BMS 1...63, default 9
- For controller set by P11 as Slave –
Address range 14...16, default 14
Cont’
PYROCON19
MASTER
MAC Address
for BMS 1...63
Default 9
A2 B2
A B
PYRO-JBOX
A B
R C
A B
R C
A B
R C
A B
R C
PYROCON19
SLAVE #1
MAC Address
14
A2 B2
A B
PYROCON19
SLAVE #2
MAC Address
15
PYROCON19
SLAVE #3
MAC Address
16
BMS or WiFi Module
MAC Address
(Slave)
MAC Address
(Master)
11
0
11
0
(Up to 3 PYROCON19 slaves)
A2 B2
A B
A2 B2
A B