Operating instructions Glass-, Dish- and Utensilwashing machine
M-iClean
9712938
We reserve the right to change execution and construction!
Page
43
of
48
18.2.1 Change of products
Change of product means that one rinse aid or detergent product is replaced by
another. The parallel use of different products can result in failures.
Hose lines and dosing units must always be rinsed out with warm water.
19
Maintenance manual
NOTE
Maintenance work should only be conducted by authorised MEIKO personnel.
Maintenance work
Visual inspection
C
H
E
C
K
E
D
C
LE
A
N
E
D
R
E
P
LA
C
E
D
Maintenance requi-
rement
1. Error memory
Check error memory for unusual events.
at least once a year
2. Electrical installation
Retighten all screw connections (e.g. heating contac-
tors, control fuse), check plug/terminal connections.
at least once a year
Carry out a visual check on all electrical equipment
(e.g. switches / cables / connector, etc.).
at least once a year
Check tank and boiler heating
at least once a year
3. Pumps
Check pumps for leaks and any visible damage.
at least once a year
Check pumps for pump rotor noise and function.
at least once a year
4. Wash tank, wash- and final rinse system
Functional and visual inspection for washing and final
rinse arms.
at least once a year
Replace sealing ring wash arm.
at least once a year
Check the air trap tank.
at least once a year
Check level control tank for leak tightness.
at least once a year
Check sieves and filter.
at least once a year
Check wash- and final rinse system for leak tightness.
at least once a year
Check water level in tank.
at least once a year
Check door seal
at least once a year
Check seal coarse sieve/drain pump
at least once a year
Replace flap ventilating valve
at least once a year
5. Housing
Check housing, tank and claddings for damage and
correct operation.
at least once a year
Check door and door counter balance for correct op-
eration.
at least once a year
6. Fresh water installation
Check valves, clean dirt trap.
at least once a year