Operating instructions Glass-, Dish- and Utensilwashing machine
M-iClean
9712938
We reserve the right to change execution and construction!
Page
36
of
48
No.
Display text
Note / possible cause
Measures / remedial action
201
Level not reached after
end of maximum final
rinse duration.
Booster pump without function.
Level detection defective.
Final rinse system clogged.
You cannot continue working
with the machine.
Call a service engineer
203
Final rinse temperature
not reached
Boiler set temperature is not
reached.
Temperature probe defective.
Heating defective.
E/A board is defective.
You can continue using the
machine!
If the error message reoccurs,
call a service engineer.
205
Maximum final rinse
cycles insufficient
Hollow vessels arranged incor-
rectly in the basket and thus
full of wash water.
Ventilating valve clogged.
Arrange the hollow vessels
correctly.
If the error message reoccurs,
call a service engineer.
206
Wash time increase final
rinse insufficient.
Temperature probe defective
Boiler heating defective
Supply valve does not close.
If the error message reoccurs,
call a service engineer.
207
No signal from boiler
level sensor
Cable break in wiring.
Pressure sensor defective.
You cannot continue working
with the machine.
Call a service engineer
208
Temperature sensor
shortcut boiler body
Short-circuit in the wiring.
Temperature sensor defective.
You cannot continue working
with the machine.
Call a service engineer
209
Temp. Sensor boiler
body interrupted
Wire break in the cabling.
Temperature sensor defective.
You cannot continue working
with the machine.
Call a service engineer
212
Forced drainage due to
permanently filled boiler
The boiler had not been
drained for a long period of
time.
Change the water or drain the
machine at least once a day.
213
Booster Pump or air
catch defective
Booster pump without function.
Level detection defective.
Final rinse system clogged.
If the error message reoccurs,
call a service engineer.
301
Shortage of rinse aid
Rinsing aid empty.
Measuring electrodes soiled.
Refilling with rinse aid;
Clean the measuring elec-
trodes.
311
Shortage of detergent
Detergent empty.
Measuring electrodes soiled.
Refilling of detergent;
Clean the measuring elec-
trodes.
405
Advance report: pre-filter
exhausted
Pre-filter soon exhausted.
Procure a pre-filter and replace
when message 408 is dis-
played.
406
Advance report:
cartridge exhausted
Cartridge soon exhausted.
Procure a demineralisation
cartridge and replace when
message 407 is displayed.
407
Change demineralization
cartridge
Demineralization cartridge is
exhausted
Replace the demineralisation
cartridge, and reset the coun-
ter.
408
Change osmosis system
pre-filter
Pre-filter exhausted
Replace the pre- filter, and
reset the counter.