107
Tank level sensor no
signal
Cable break in wiring.
Pressure sensor defective.
You cannot continue working
with the machine.
Call a service engineer.
108
Tank temperature sen-
sor shortcut
Short-circuit in the wiring.
Temperature sensor defective.
You cannot continue working
with the machine.
Call a service engineer.
109
Temp. sensor wash
tanks interrupted
Wire break in the cabling.
Temperature sensor defective.
You cannot continue working
with the machine.
Call a service engineer.
111
Water loss in wash tank
Ventilating valve clogged.
Leakage in level control sys-
tem.
If the error message reoccurs,
call a service engineer.
112
Forced drainage due to
permanently filled wash
tank.
The tank had not been drained
for a long period of time.
Change the water or drain the
machine at least once a day.
114
Fine/coarse sieve mis-
sing
Fine/coarse sieve not availa-
ble.
Inserted incorrectly.
Cable break.
Sensor defective.
Magnet missing.
Insert the fine/coarse sieve
correctly.
If the error reoccurs, call a ser-
vice engineer.
115
Drain pump active after
triggering of the safety
level
Tank overfilled.
Supply valve does not close.
Drain pump actuated until level
of operation reached.
You can continue using the
machine!
117
Top wash system
blocked/missing.
Error detecting the rotating
arm.
Washing pump not functioning.
Ensure top wash arm system
can move freely.
If applicable, insert top wash
arm system.
If needed, remove dirt particles
and ferric metal particles from
the magnet.
118
Bottom wash arm sys-
tem blocked/missing.
Error detecting the rotating
arm.
Washing pump not functioning.
Ensure bottom wash arm sys-
tem can move freely.
If applicable, insert bottom
wash arm system.
If needed, remove dirt particles
and ferric metal particles from
the magnet.
127
Temperature increase
not reached
Tank set tempera-
ture/temperature increase is
not reached.
Temperature probe defective.
Heating defective.
E/A board is defective.
If the error message reoccurs,
call a service engineer.
200
Boiler level during filling
not reached early
enough.
No or insufficient water inlet
water supply.
Open water inlet valve.
Check pre-filter/sieve and
clean or replace (if applicable).
If needed, call a service engi-