Operating instructions Glass-, Dish- and Utensilwashing machine
M-iClean
9712938
We reserve the right to change execution and construction!
Page
30
of
48
11
Cleaning instructions
–
daily
WARNING
Danger of scalding/burning!
The tank heating element may still be hot after the tank has been emptied. There is
therefore a risk of burning or scalding when the machine is cleaned manually!
Please observe appropriate protective measures.
Damage to property
The machine, switch cabinets and other electrical components must NOT be sprayed
with a hose or a high pressure cleaner!
Avoid flooding the base of the machine to prevent damage to components from pen-
etrating water!
After the tank has been drained:
Food residues sticking to the tank, tank heating element and sieves must be re-
moved with a brush.
Do not use a foaming detergent for pre-cleaning or cleaning of the machine. Foam
can cause malfunctions in the dish-washer and a poor wash.
Remove the washing/final rinse arm and rinse it.
Magnet
As part of daily cleaning, re-
move all dirt particles and parti-
cles containing iron that adhere
to the magnet so the sensor
detects the rotation of the rinse
arm.
Clean nozzles using running water each day.
Remove the sieve including the filter and rinse individually.
Clean the inner chamber.
Inspect the main pump sieve for con-
tamination daily and clean as neces-
sary. To clean the sieve, remove it
and rinse under running water.
Refill
all
parts.