Test fail screen
Should an asset fail a test at any stage, the test sequence is stopped and the screen message ASSET FAILED is displayed:
Example:
Asset has failed the insulation test.
Pass limit set to 1.0 MΩ, Measurement recorded at < 0.1 MΩ.
The same options are available as an asset that has passed. See Section 3.7 for completion of testing.
3.9
Visual failure
If the current test group contains a visual test sequence then the visual test popup will appear. This allows the user to log mechanical
faults on the asset under test, such as a broken plug or damaged appliance cord, the Esc key should be used to exit the test sequence
during the Visual Inspection and initiate a Visual Failure, as below:
1)
During the Visual inspection option the “Visual Test” will be highlighted in yellow, as below:
2)
Press the Esc key to initiate a Visual Failure. The display will show a Visual Test Failure screen as below:
3)
Three types of information can be entered:
a)
Notes
- To describe the type of failure.
b)
Check boxes
- Quick entry for standard failure types.
c)
Repair code
- See Section 3.10 below
4)
Press the TEST key to complete the test process. The display will now show the TEST FAILED screen.
5)
Press the SAVE Hotkey to save the results or the SAVE and PRINT Hotkey to save the results and print a barcode label.
SAVE results to memory
Print bar code label & SAVE
results to memory
Repair codes
Repeat test sequence