- 84 -
If the EAS alert data is accurate, and you are ready to issue the alert, click on
the
Yes, Send Alert!
button. The alert will be "originated", that is, played,
out of the selected One-Net audio output ports. The originated alert audio
ports are selected from either the
Setup Encoder > Audio
or the
Setup Audio
> Encoder
screens. See section 5.6.3.
During the origination time, the front panel red LED will be lit and the audio
of the alert will play from the built-in One-Net internal speaker. For the
duration of the issued alert, the One-Net will periodically crawl the alert text
across the front panel LCD. The LCD text for the letter “O” will precede the
alert, indicating a One-Net originated alert. The details of this alert will be
viewable on the screen Encoder Originated Alert Status [
Encoder >
Originated Alerts
].
7.1.2. One-Button
EAS
The One-Net allows required weekly tests to be preconfigured on the
Setup >
Encoder > Required Tests
page. Once these have been configured, the
Encoder > Send EAS > One-Button EAS
page will present a button to issue
the alert. This makes it simple to send these test alerts, without having to
select details. The alert start time is set to be effective immediately. The
serial interface status and bypass are also present as in the
General EAS
screen. See section 7.1.1
7.2. Originated
Alerts
The Encoder Originated Alert Status page is organized just like the Decoder Decoded
Alert Status page. You can look at the details of every alert originated from the One-
Net. The following types of alerts are displayed:
•
Scheduled Originated Alerts. Scheduled alerts occur when random Weekly tests
are automatically scheduled and when specific alerts are sent starting at a future
time.
•
Currently Active Originated Alerts
•
Expired Originated Alerts
You can select specific dates for expired alerts using the FROM and TO date
selection pull-down menus or the other choices shown under the Decoded Alerts
Section 6.1.
Summary of Contents for R189
Page 22: ... 21 ...
Page 26: ... 25 ...
Page 54: ... 53 Message Display Control This selection determines how the message is repeated ...
Page 73: ... 72 ...
Page 90: ... 89 11 Connection Diagrams 11 1 Baseband System ...
Page 91: ... 90 11 2 Comb System ...
Page 92: ... 91 11 3 KeyWest Crawl System ...
Page 93: ... 92 11 4 KeyWest Crawl System with Starmu ...
Page 94: ... 93 11 5 KeyWest Crawl System with Starmu ...
Page 95: ... 94 11 6 Cable Envoy Crawl System ...
Page 96: ... 95 11 7 R194 Crawl System ...