Page 15
Installation
optoNCDT ILR 1181 / 1182
5.
Installation
The sensor optoNCDT ILR 1181-30/1182-30 is an optical sensor for measurements with millimeter accuracy.
Make sure it is handled carefully when installing and operating.
5.1
Sensor Mounting
The sensor is be mounted by means of 4 screws type M6 DIN 934 and two groove stones in the installation
slots. The laser beam must be directed perpendicularly onto the surface of the target. In case of misalign-
ment it is possible that the measurement results will not always be accurate.
The sensor will be aligned by a visible laser beam with the target. To align the sensor, please comply with the
“Instructions for Operation“, see Chap.
6.
99
(3.88)
36
(
1.42)
56
(2 2)
7.3
(0.29)
84.4
(3 32)
25.5
(1.0)
51
(2.0)
17.5
(.69)
16
(.63)
ø50
(1.97)
41.9
(1.65)
144
(5.67)
194
(7 64)
M6
slot nuts