Page 24
Operation
optoNCDT ILR 1181 / 1182
AH
AW
AH
HIGH LOW
LOW HIGH
+AH -AH
Dist.
AC
Fig. 14 Digital switching output behavior with positive and negative hysteresis
Example:
A moving object is assumed to be monitored within a window of 10 m to 11 m with a hysteresis of 0.2 m.
Consecutively you find the parameters AC, AW and AH in dependence on SF:
- AC2 / AH0.2 / AW3 / SF1
- AC2000 / AH200 / AW3000 / SF1000
Distance (m) increases
1.8
1.9
2.0
2.1
2.2
...
5.0
5.1
5.2
+AH
L
L
L
H
H
H
H
L
L
-AH
H
H
H
L
L
L
L
H
H
Distance (m) decreases
5.2
5.1
5.0
4.9
4.8
...
2.0
1.9
1.8
+AH
L
L
L
L
H
H
H
H
L
-AH
H
H
H
H
L
L
L
L
H
L = LOW, H = HIGH
How the switching output is to behave on occurrence of an error message (E15, E16, E17, E18) can be de-
fined by making suitable settings under “SE“, see Chap.
7.3.6
.