MDS 05-6628A01, Rev. B
MDS Orbit MCR-4G Technical Manual
19
admin@(none) 05:40:15%
exit
[ok][2012-06-20 05:40:17]
admin@(none) 05:40:17>
Step 7: Exit the login session by typing the following, followed by the enter key:
exit
admin@(none) 05:40:32>
exit
(none) login:
CLI Quick Reference Table
Table 7
provides a summary listing of commonly-needed tasks and the appropriate commands to enter. The
table can be used as a quick reference before consulting the more detailed information which follows in this
section. Each CLI command is proceeded by the symbol
>
for operational command, or
%
for a configura-
tion command.
Table 7. CLI Quick Reference Table
If you wish to...
Enter this CLI command:
Create a one-time password
>request system recovery one-time-password create function
<userfunction>
View all network interface
status and statistics
>show interfaces
Create a bridge
%set interfaces interface myBridge virtual-type bridge
Add an interface to a bridge
%set interfaces interface myBridge bridge-settings members port
ETH1
Remove an interface from a
bridge
%delete interfaces interface myBridge bridge-settings members port
ETH1
View WiFi settings
>show configuration interfaces interface Wi-Fi wifi-config | details
Set WiFi AP SSID
%set interfaces interface Wi-Fi wifi-config mode access-point
ap-config ap myssid
Enable WiFi WPA2-Personal
security
%set interfaces interface Wi-Fi wifi-config mode access-point
ap-config ap myssid privacy-mode wpa2-personal psk-config psk
mypassphrase
Configure WiFi details
%set interfaces interface Wi-Fi wifi-config ap-config ap myssid
broadcast-ssid true
Monitor WiFi statistics
>show interfaces interface Wi-Fi statistics | repeat 5
View the cell module status
>show interfaces interface Cell
View the cell APN
>show configuration interfaces interface Cell cell-config apn
View the routing table
>show routing
View the event log
>show table logging event-log | nomore
Set the admin user’s
password
>request system authentication change-password user admin
password admin
Set the device name
%set system name “Mydevice”
Set the baud rate on COM1
%set services serial ports COM1 baud-rateb19200