15
REPAIR
Number of flashes
Fault - repair
1
The battery needs to be charged or it has not been properly connected.
Check the battery connection or charge the battery.
2
Left motor has not been properly connected.
Check the motor connection.
3
There is a short circuit between the left motor and the battery.
Contact your distributor.
4
Right motor has not been properly connected.
Check the motor connection.
5
There is a short circuit between the right motor and the battery.
Contact your distributor.
6
The wheelchair is stopped by the charger.
Disconnect the charger.
7
Control shifter defect has been detected.
Make sure that the shifter is in neutral position before you deactivate the
control panel.
8
Control panel defect has been detected.
Make sure that all connections have been secured.
9
Braking system has not been properly connected.
Check the connection of the braking system and connection with the
motor.
Check other connections as well.
10
Too high voltage for the control panel.
This is usually caused by faulty connection to the battery.