x
x
U
Z
49
16-CLEANING
Technical Dept. - All rights reserved - Reproduction is prohibited
CLEANING THE LOWER COMPARTMENT
At this point you can remove the four screws “x”, the plate “U” and the seal “Z” and then clean the lower compartment where all the dirt
deposits of the previous cleaning have accumulated. Even in this case, if necessary, replace the gasket “Z”.
CLEANING THE SMOKE EXHAUST SYSTEM AND GENERAL CHECKS
Clean the smoke extractor system, especially around the “T” joints, elbows and any horizontal sections of the smoke duct.
For information on periodically cleaning the flue, contact a skilled chimney sweep.
Check the seal of the ceramic fibre gaskets on the door of the stove. If necessary, order new replacement seals from the retailer or contact
an authorized service centre to carry out this task.
CAUTION:
The frequency with which the smoke outlet system is cleaned depends on the use of the boiler and the type of
installation.
We recommend relying on an authorised service centre for end-of-season cleaning and maintenance, as they will
carry out all of the previously mentioned work and inspect the stove components.