44
14-ALARMS
SOLUTIONS:
If “
A03
” appears: the structure is too hot because the product has been used for too long at the maximum power or there is poor ventilation.
When the product is sufficiently cold, press button B on the control panel or
OFF
on the remote control to cancel alarm
A03
. Once the
alarm is cancelled, the product can be switched on normally.
If “
A04
” appears: The stove switches off automatically. Let the stove cool down for a few minutes and then switch it on again. Check the
smoke expulsion and verify the type of pellet used according to the instructions found in Chap. 2 of this manual.
If “
A05
” appears: the door has been left open for too long or a significant amount of air has entered (e.g. missing smoke fan inspection
cap). If these causes are excluded, check and if necessary clean the smoke duct and flue. (it is recommended that this operation is carried
out by an MCZ qualified technician.
The product can be switched on again only after having eliminated the cause permanently.
ALARM A18: PELLET TANK OPEN, FIRE DOOR OPEN AND AIR PRESSURE SWITCH