11-EMERGENCY PANEL
The emergency panel is found at the back of the stove. The panel is used to detect any malfunctions and also for product control if the
remote control is not working.
KEY
A - DISPLAY; indicates a series of information on the stove, as well
as the identification code of any malfunction.
B - GREEN LED that indicates:
• OFF = Stove off
• FLASHING ON = Stove in ignition stage
• FIXED ON = Stove on
C - RED LED that indicates:
• OFF = Stove on
• ON WITH SLOW FLASHING = Stove in shutdown stage
• ON WITH FAST FLASHING = Stove in alarm conditions
(combined with a beep sound for the first 10 minutes)
• FIXED ON = Stove off
D - Three-position selector for the following functions
• OFF = Stove switched off manually without remote control
• REMOTE = Stove controlled
exclusively
from the remote
control
• ON = Stove switched on manually without the remote control
E - Three-position selector to select the power
• MIN = Selector to make the stove work at MINIMUM power
without the remote control and with selector 4 on ON
• MED = Selector to make the stove work at MEDIUM power
without the remote control and with selector 4 on ON
• MAX = Selector to make the stove work at MAXIMUM
power without the remote control and with selector 4 on
ON
F - Button for diagnostic functions relating to the operating
status of the stove
G - Button to put the stove in communication with a new remote
control (via the procedure explained in the Remote Control
Synchronisation" paragraph)
H - Reception antenna
SELECTOR "D" MUST BE SET ON "REMOTE" TO
MAKE THE STOVE OPERATE WITH THE REMOTE
CONTROL.