Room ventilation
Room ventilation can be adjusted as desired in all 4 operating modes described above (Manual, Automatic, Timer, Eco). Simply perform
this operation: from the basic display, press key D to access the VENTILATION adjustment mode (Fig. 6). Then press key C (arrows) to set the
desired ventilation by selecting one of the 5 levels available, independent from the flame level.
The “auto” option can also be selected, which automatically links the room ventilation speed to the flame level.
In short:
flame set on 1 > ventilation set on 1; flame set on 3 > ventilation set on 3; flame set on 5 > ventilation remains set on 3 (for silent
operation as it is in automatic mode).
NOTE: In the event a replacement remote control is purchased, if you need to change the default setting, proceed as
follows: with the remote control switched on press buttons D + E at the same time for 10 seconds (until the flashing
number appears). Press button C to select 1, exit and confirm with E.
IMPORTANT! Choosing the right number of fans can become a decisive factor to ensure the stove works correctly. Therefore
ensure an authorised technician conducts the settings.
The list of fans in place is shown in the table:
STOVE MODEL
NO. OF FANS
EGO 2.0 AIR OYSTER
1