SERVICE AND MAINTENANCE
Service Parts
Indoor air fi lter
Indoor unit
Maintenance Procedures
Period
1. Remove any dust adhering to the fi lter by using a vacuum cleaner or wash in
lukewarm water (below 40°C/104°F) with a neutral cleaning detergent.
2. Rinse the fi lter well and dry before placing it back onto the unit.
3. Do not use gasoline, volatile substances or chemicals to clean the fi lter.
1. Clean any dirt or dust on the grille or panel by wiping it with a soft cloth
soaked in lukewarm water (below 40°C/104°F) and a neutral detergent
solution.
2. Do not use gasoline, volatile substances or chemicals to clean the indoor
unit.
At least once every 2
weeks.
More frequently if
necessary.
At least once every 2
weeks.
More frequently if
necessary.
Recess on
main unit
Rotating
shaft
1. Open the front panel.
• Hold the panel at the recesses on the main unit (2
recesses on right and left sides) and lift it until it
stops.
2. Remove the front panel.
• While lifting the front panel further, slide it to the right
and pull it to the front side. The left rotating shaft is
detached. Slide the right rotating shaft to the left and
pull it to the front side to remove it.
3. Attach the front panel.
• Align the right and left rotating shafts of the front
panel with the grooves and push them all the way
in.
• Gently close the front panel. (Push both ends and
the center on the front panel.)
• Do not touch the metal parts of the indoor unit. It may cause an injury.
• When removing or attaching the front panel, support the panel securely with hand to prevent it from falling.
• For cleansing, do not use hot water above 40°C, benzine, gasoline, thinner, nor other volatile oils, polishing
compound, scrubbing brushes, nor other hand stuff.
• After cleaning, make sure that the front panel is securely fi xed.
CAUTION
When The Unit Is Not To Be Used For An Extended Long Period Of Time
Operate the unit for 2 hours
with the following setting.
Operating mode : cool
Temperature : 30°C/86°F
Remove the power plug.
If you are using an independent
electric circuit for your unit, cut
off the circuit.
Remove the batteries in the
remote control.
• Avoid direct contact of any coil treatment cleaners on plastic part. This may cause plastic part to deform as a
result of chemical reaction.
CAUTION
MacQuay IM-WMJ-1110(0).indd 13
MacQuay IM-WMJ-1110(0).indd 13
1/12/2011 6:26:01 PM
1/12/2011 6:26:01 PM
Summary of Contents for M5LCY10FR
Page 2: ......
Page 16: ...1 14 MEMO...
Page 17: ...1 15 h s i l g n E E ng li sh MEMO...
Page 18: ...1 16 MEMO...
Page 32: ...2 14 PROMEMORIA...
Page 46: ...3 14 MITTEILUNG...
Page 60: ...4 14 EL MEMOR NDUM...
Page 74: ...5 14 LE M MO...
Page 88: ...6 14 NOT...
Page 91: ...h s i l g n E 7 3 CTOPO HO OFF H MAH E 1 1 PE PE EH E...
Page 92: ...7 4 R410A 1 1975 1 A B A B 1 2 2 3 4 5 6 2...
Page 93: ...h s i l g n E 7 5 1200 30 e 50 1 2 3 250 M4 X 12L Hapy 100 100 150 50 150 300 50 50 100 1200...
Page 94: ...7 6 T T T H 1 2 30 3 16 50 50 30 y ox c...
Page 99: ...h s i l g n E 7 11 C 1 o 2 1 O O O K K K...
Page 100: ...7 12 1 2 2 3 4 CWB CDB CDB CWB...
Page 106: ......
Page 107: ...CDB CWB CWB CDB WB DB...
Page 108: ...IR OFF ON ON OFF LED LED IR IR ON OFF LED LED ON...
Page 110: ...1 2 SIG N L 2 1 SIG H07RN F A...
Page 111: ...L L A B C D A B C A D A D...
Page 112: ...166 184 181 7 55 5 54 5 153 8 263 51 9 800 9 5 4 2 2 4 8 8 2 2 2 4 9 5 4...
Page 113: ......
Page 114: ...M4 x 12L...
Page 115: ...R410A 1975 GWP GWP 1 2 2 1 2...
Page 116: ...OFF ON OFF ON OFF...
Page 117: ...E D B C I H G N J L K F A M5LCY10 15FR A B C D E F G H I J K L M N M5LCY10 15FR...
Page 118: ...M5WMYL A B C D E F G H I J K L M M5WMY10 15LR A B C B ON OFF H I F E J G G L D B K M A F...
Page 119: ......
Page 120: ...2010 McQuay International L IM 5WMYJ 1110 0 McQuay R08019035856...