IOMM ACZ/AGZ-1
55
Figure 26, Zone Terminal
MONITOR
ADJUST
TIME SCHEDULE
PASSWORD
ENTER
Com press or 1
Com press or 2
Sta ge 3
Sta ge 4
Sole noid #1
Frz stat #1Al m
Frz stat #2Al m
Min LowP res# 1
Min LowP res# 2
Occ upied
Flo w Fa ilur e
OA Lock out
Cir #2Le ad=O n
Pmp /Stp #1= 0
L vg W ater Temp
Ev ap Pr es #1
Ev ap P res # 2
OA/A I3 In put
Lv gWtr RBnd SP
Co ntrl Band SP
Act ual Lvg S P
Uno ccpd Lvg SP
OA Lo ckou t SP
Lvg Low Lim S P
Soft Sta C apcty
Ci r #1 Star ts
Cir #2 Start s
McQuay AGZ/AGR Global Chiller
INSERT 10
ON OFF
Disp lay
Button 1
Mode
Se lector
Pa nel
Mode
Sele ctor
Button
2
AGZ-AGR
Disp lay In dicato r Dot
O n/Off Status
3
Operating Mode Indicator
Up/Down Arrow Keys
Door
Displa y Ite m List
Wa rning Sig nal
A LARM
OA/A I3 Hi LimSP
OA/A I3 Re setSP
Display Area 1
1
Display Area 2
1
Display Area 3
1
Alarm Light
Lvg Wate r SP
% U nit Load
Soft Start Time
Pm p/St p #2 =0
Sole noid #2
St age 5 Op t.
Stag e 6 O pt.
OPERATING MODES
Two operating modes are included: Monitor and Adjust.
Monitor Mode
As soon as the ZT is connected, it completes a self-check, and starts up in the Monitor Mode.
Monitor Mode lets you view up to three of chiller settings/sensed values at a time.
To allow you to monitor your system, a clear plastic Insert (factory made and installed) relates the
ZT’s output to your McQuay Global UNT controller.
You can simultaneously monitor the chiller in three ways:
•
Monitor up to three settings/sensed values. A maximum of six items are accessible in each of the
three displays.
•
Read the symbols to the right of the display numbers to learn the on/off status of various inputs,
outputs, or modes (| = On status; m = Off status). This provides continuous monitoring of 18
different status (on/off).
•
Monitor alarm status–a flashing red alarm light and any flashing symbol ( |, m, s) visually notifies
you when your chiller has an alarm condition.
Adjust Mode
In Adjust Mode, the ZT displays information in each of the three numerical displays. Typically, the
displays are set up so that the relationship between the values can be viewed simultaneously. For
example:
Display 1 = Lvg Water Temp
Display 2 = Lvg Water SP
Display 3 = % Unit Load
This operating mode allows you to adjust any flashing setpoints. Setpoints adjusted by the ZT
remain in effect until you change them.
Summary of Contents for ACZ 045A
Page 6: ...6 IOMM ACZ AGZ 1 Figure 3 Clearance Requirements...
Page 27: ...IOMM ACZ AGZ 1 27 Figure 12 AGZ AM Single point Connection with FanTrol...
Page 28: ...28 IOMM ACZ AGZ 1 Figure 13 AGZ AM Single point Connection with SpeedTrol...
Page 29: ...IOMM ACZ AGZ 1 29 Figure 14 AGZ AM Unit Control Schematic UNT...
Page 30: ...30 IOMM ACZ AGZ 1 Figure 15 AGZ AM Staging Schematic UNT...
Page 31: ...IOMM ACZ AGZ 1 31 Figure 16 AGZ AM MicroTech Controller Schematic...
Page 32: ...32 IOMM ACZ AGZ 1 Figure 17 AGZ AM Unit Control Schematic MicroTech...
Page 33: ...IOMM ACZ AGZ 1 33 Figure 18 AGZ AM Staging Schematic MicroTech...
Page 34: ...34 IOMM ACZ AGZ 1 Figure 19 ACZ Field Connection Diagram No Capacity Control...
Page 35: ...IOMM ACZ AGZ 1 35 Figure 20 ACZ Field Wiring Diagram Capacity Control Staging...
Page 104: ...Post Office Box 2510 Staunton Virginia 24402 2510 USA 800 432 1342 www mcquay com...