PBXgateway II Quick Installation Guide
38
Definity PBX ConneX Configuration
The instructions below are applicable for the configuration of Avaya’s DEFINITY ECS running release 3
or higher:
SCENARIO #1: Office Phone Used in Conjunction with the ConneX Phone
There is only one change required on the user’s office extension when he/she wishes to use the ConneX
phone as a complementary business tool. The number of rings should be increased to six (06) before
going into voicemail. This is required to allow enough time for the gateway to call the ConneX phone.
Note: No wiring changes are required on this extension.
Note: This extension MUST be capable of DID
.
1. Perform
a
change station
to modify the
Coverage Path
of the user’s office extension to allow it to
ring 6 times before going into voicemail.
Tech Tip:
Create a new
Coverage Path
in the DEFINITY to
accommodate this “class” of users.
2. Hit
the
Enter
key on the number pad (far right of keyboard) to save the change made to this
extension.
Provisioning a New Extension for the ConneX Phone
1. Provision a new extension for the ConneX phone (Ch1) on the DEFINITY. Wire this extension into the
ConneX PBXgateway on an available port.
Note: This extension does NOT require DID capability
.
2. Go to Page 1 of the Definity terminal session to configure the CH1 extension.
3. Change
Type
to a DEFINITY phone set that supports the “analog adjunct” feature. We recommend
phone set
8411D
, however other phones like the
6416D+
and
6424D+
also support the analog
adjunct feature. Notice the
Data Option
field appears in the middle of the screen when this change is
made.
Tech Tip
: It is NOT necessary for the phone type to match the type used at the office
extension, since only the first ten (10) line/feature buttons are accessible from a mobile phone.
4. Complete
the
Name
field. Be sure to give this extension a clear name (i.e. ConneX Port 1).
5. Change
Data Option
to
analog
(notice the page number increases by 1 when this change is made).
6. Change
the
Message Lamp Ext
to the user’s office extension.
7. Go to Page 2 and set
Bridged Call Alerting
to Y.
8. Go
to Page 3 of the DEFINITY terminal session for this extension (Ch1).
9. On Page 3: Change
all
call-appr
assigned buttons to
brdg-appr
→
Btn:
assignment #
→
Ext:
Office
Extension.
Note: Program keys 0-9 on this extension to match the office phone’s keys 0-9. This is
required to make the features accessible from the mobile phone.
10 Go
to last page (note: last page number may vary depending on phone model). Heading should read
Analog Adjunct
.
11. On last page: Assign the
Data Extension
a new or unused extension (Ch2) on the DEFINITY.
This
extension MUST be capable of DID
. This is the extension number that the ConneX users will call to
access the RCX. This will either be a DID extension, or accessible through a transfer from a main
number (i.e. Intuity, Vector, IVR,etc.).
12. Type in the extension
Name.
Give this extension a descriptive name so it is clear what it is being
used for (i.e. Username B2 - Mobile #1).
13. Hit
the
Enter
key on the number pad (far right of keyboard) to save all changes made to extension
Ch1 and its now corresponding extension Ch2.