C
C-50
E/OS SNMP Support Manual
McDATA Private Enterprise MIB
Status
mandatory
Description
The number of minutes in a threshold alert interval.
Sequence
::= { fcEosTAEntry 7 }
fcEosTATriggerValue
Syntax
INTEGER
Access
read-only
Status
mandatory
Description
If the alert type is a Throughput Threshold Alert, then this is the
percent utilization (1-100) required to trigger an alert. If the alert type
is a Counter Threshold Alert, then this is the counter delta required to
trigger an alert.
Sequence
::= { fcEosTAEntry 8 }
fcEosTTADirection
Syntax
INTEGER { transmit (1), receive (2), either (3) -- (Tx or Rx) }
Access
read-only
Status
mandatory
Description
This only applies when the alert type is a Throughput Threshold
Alert. It specifies the throughput direction of the threshold.
Sequence
::= { fcEosTAEntry 9 }
fcEosTTATriggerDuration
Syntax
INTEGER
Access
read-only
Status
mandatory
Description
This only applies when the alert type is a Throughput Threshold
Alert. It specifies the amount of time during a threshold alert interval
that the trigger must be exceeded before an alert is generated.
Sequence
::= { fcEosTAEntry 10 }
Summary of Contents for 316095-B21 - StorageWorks Edge Switch 2/24
Page 1: ...E OS SNMP Support Manual P N 620 000131 630 REV A ...
Page 22: ...1 1 10 E OS SNMP Support Manual Introduction to SNMP ...
Page 248: ...A A 78 E OS SNMP Support Manual Fibre Alliance MIB ...
Page 324: ...B B 76 E OS SNMP Support Manual FC Management MIB ...
Page 380: ...C C 56 E OS SNMP Support Manual McDATA Private Enterprise MIB ...
Page 500: ...F F 10 E OS SNMP Support Manual SNMP Framework MIB ...