B
Event Group
B-53
FC Management MIB
Access
read-only
Status
mandatory
Description
Count of times that PBSY was returned to this port as a result of a
frame that could not be delivered to the other end of the link. This
occurs if the destination port is temporarily busy. PBSY can only
occur on SOFc1 frames (the frames that establish a connection). Note,
this is a Fibre Channel only stat.This is the sum of all classes. If you
cannot keep the by class counters, then keep the sum counters.
Sequence
::= { connUnitPortStatEntry 11 }
connUnitPortStatCountFRJTFrames
Syntax
OCTET STRING (SIZE (8))
Access
read-only
Status
mandatory
Description
Count of times that FRJT was returned to this port as a result of a
Frame that was rejected by the fabric. Note, This is the total for all
classes and is a Fibre Channel only stat.
Sequence
::= { connUnitPortStatEntry 12 }
connUnitPortStatCountPRJTFrames
Syntax
OCTET STRING (SIZE (8))
Access
read-only
Status
mandatory
Description
Count of times that FRJT was returned to this port as a result of a
Frame that was rejected at the destination N_Port. Note, This is the
total for all classes and is a Fibre Channel only stat.
Sequence
::= { connUnitPortStatEntry 13 }
connUnitPortStatCountClass1RxFrames
Syntax
OCTET STRING (SIZE (8))
Access
read-only
Status
mandatory
Summary of Contents for 316095-B21 - StorageWorks Edge Switch 2/24
Page 1: ...E OS SNMP Support Manual P N 620 000131 630 REV A ...
Page 22: ...1 1 10 E OS SNMP Support Manual Introduction to SNMP ...
Page 248: ...A A 78 E OS SNMP Support Manual Fibre Alliance MIB ...
Page 324: ...B B 76 E OS SNMP Support Manual FC Management MIB ...
Page 380: ...C C 56 E OS SNMP Support Manual McDATA Private Enterprise MIB ...
Page 500: ...F F 10 E OS SNMP Support Manual SNMP Framework MIB ...