SCSI Description
Maxtor Atlas 15K
5-23
Table 5-25
Standard Inquiry Data Page-Field Descriptions
Note:
Vendor Information, Product Identification, and Product
Revision Level are returned as shown in Table 5-22.
Field Name
Value
Description
Peripheral Qualifier
0
Non-zero if initiator selects an invalid logical unit.
Peripheral Device
0
0 indicates that this is a Direct Access Device.
ANSI Version
3
ANSI SCSI Level 3 (SCSI-3) is supported.
AERC
0
Asynchronous Event Reporting is not supported.
NormACA
0
Does not support setting NACA in CDB Control word.
Port
0
Only used when MultiP = 1.
MultiP
0
This field set to 1 if it is a multiport device.
Mchngr
0
Not embedded in or attached to a medium changer
ACKQREQQ
0
Device supports REQ and ACK data handshake on Q cable.
Addr32
0
32-bit wide SCSI address
Addr16
0/1
16-bit wide SCSI address
TrmTSK
0
TERMINATE TASK Function is not supported
Response Data
Format
2
This Standard Inquiry Data is in the format specified in the International Standard.
RelAdr
0
Relative Addressing is not supported.
WBus 32
0
32-bit wide bus is not supported.
WBus 16
0 or 1
The WBus bit is 1 if the drive supports 16-bit data transfer. The bit is 0 if the drive only
supports 8-bit transfer.
Sync
1
The drive supports Synchronous Data Transfers.
Linked
1
Linked Commands are supported.
TransDis 1
Indicates that the drive supports CONTINUE TASK and TARGET TRANSFER DIS-
ABLE messages.
CmdQue
1
The drive supports Tagged Command Queuing
SftRe 0
The drive implements the hard reset option in response to assertion of the SCSI Bus reset
line.
VS
0
Vendor Specific
Product
Identification
The
value in
this field
is:
ATLAS15K_18WLS, ATLAS15K_36WLS, ATLAS15K_73WLS
ATLAS15K_18SCA, ATLAS15K_36SCA, ATLAS15K_73SCA
Clocking 11
The contents of this field define the setting of the double-edge clocking option (See Chap-
ter 6). Note that the clocking field does not apply to asynchronous transfers of data. Op-
tions available are:
Code
00b
01b
10b
11b
Description
Indicates the device server supports only Single Transition
(ST)
Indicates the device server supports only Double Transition
(DT)
Reserved
Indicates the device server supports ST and DT
QAS 1
(U160)
Quick Arbritrate Support. If the value of this field is 1, it indicates that the device server
supports the quick arbitrate feature. A value of 0 indicates that the device server does not
support this feature. 1 is default setting.
IUS 1
(U320)
Information Unit Supported. If the value of this field is 1, it indicates that the device server
supports information units. A value of 0 indicates that the device server does not support
information units. Default is 1.
Summary of Contents for Atlas SCSI Drive 15K II
Page 1: ...Maxtor Atlas 15K Product Manual ...
Page 2: ...Maxtor Atlas 15K Product Manual April 29 2003 PN 1880 ...
Page 6: ......
Page 12: ...Table of Contents xii Maxtor Atlas 15K ...
Page 14: ...List of Figures xiv Maxtor Atlas 15K ...
Page 24: ...About This Manual 1 4 Maxtor Atlas 15K ...
Page 53: ...Installation Maxtor Atlas 15K 3 25 Figure 3 9 Crosswise Airflow Cooling ...
Page 54: ...Installation 3 26 Maxtor Atlas 15K ...
Page 66: ...Specifications 4 12 Maxtor Atlas 15K ...
Page 232: ...Feature Descriptions 6 16 Maxtor Atlas 15K ...
Page 238: ...Appendix A A 6 Maxtor Atlas 15K ...
Page 253: ...Glossary G 13 Maxtor Atlas 15K ...
Page 254: ...Glossary G 14 Maxtor Atlas 15K ...
Page 260: ...Index I 6 Maxtor Atlas 15K ...