EP3INBC
Meaning:
Endpoint 3-IN Byte Count Register.
Location:
EP3INBC[6:0]
Write:
The CPU loads this register with the number of bytes it has previously loaded into
the EP3INFIFO (page 22). This arms the endpoint for the next IN transfer.
Read:
The SIE sends the data in this FIFO as the response to an EP3-IN host request.
POR:
EP3INBC=0
Chip Reset:
EP3INBC=0
Bus Reset:
EP3INBC=0
Pwr Down:
Read-only
Programming Notes: