EP3DISAB
Meaning:
Disable Endpoint 3.
Location:
CLRTOGS.7
Set:
The CPU sets this bit to disable traffic to endpoint 3-IN.
Clear:
The CPU clears this bit to enable traffic to endpoint 3-IN.
POR:
EP3DISAB=0
Chip Reset:
EP3DISAB=0
Bus Reset:
EP3DISAB=0
Pwr Down:
Read-only
Programming Notes:
A disabled endpoint does not respond to any traffic. A host normally will never send traffic to an
endpoint that is not reported during enumeration, so this is a “safety” bit to guard against an
errant host.
Endpoint 0 has no disable bit because as the default CONTROL endpoint it must always be
active.