5-2
DIGITAL INPUT/OUTPUT MATRIX
www.maxcessintl.com
FIFE-500-XL
MI 2-267 1 D
Digital Output Matrix
OUTPUTS*
STATUS
D
C
B
A
LOSS OF NULL (AUTOMATIC MODE)
-
-
-
1
CENTERED (SERVO-CENTER MODE)
-
-
1
-
MOTOR BLOCKED
-
1
-
-
POWER OK
1
-
-
-
* Digital outputs are active low.
1 = ACTIVE