4-29
MENU DESCRIPTIONS
www.maxcessintl.com
FIFE-500-XL
MI 2-267 1 D
AUTOSETUP
The FIFE-500-XL Web Guiding System gain and polarity can
be set manually as described in other areas of this manual. Using this menu
however, the system gain and polarity can be determined automatically.
Navigation:
MANUAL
SELECT SENSOR MODE
SETUP
AUTOSETUP
Note: The auto setup procedure should be done with the web at a standstill.
Auto setup is performed using the sensor mode that has been selected from
the Operator Level screen. Before auto setup can begin, the web must be
within the selected sensor field of view. The bar graph indicator shows the
acceptable limits for the sensor signal and the AUTOSETUP button will
remain disabled until the correct conditions are present.
Use the jog buttons to position the web edge near the center
of the sensor proportional band as shown below.
Press the AUTOSETUP button to start. The guide will move a short distance
as it completes the auto setup process. Successful completion is indicated by
the message shown below.