4-20
MENU DESCRIPTIONS
www.maxcessintl.com
FIFE-500-XL
MI 2-267 1 D
Navigation:
MANUAL / SERVO-CENTER / AUTOMATIC
SETUP
ASC
ASC SETTINGS
Touch the tab controls at the top as needed to switch to the desired
page before making changes.
ASC State The ASC State button enables or disabled the availability of
ASC use for the selected sensor mode. The LED displayed on the button
indicates the present state. Press the button to toggle the ASC
availability for this sensor mode on or off.
Source Selects the sensor that is monitored for ASC thresholds.
Typically this is the same sensor used for guiding but in some
applications it could be desirable to monitor a different input. Source
input choices include the sensor signal S1, S2, S1+S2, or S1S2.
Mode The mode setting controls how the source signal threshold is
processed. These modes are used configure ASC operation for specific
application requirements. There are 6 modes available:
Above +
Signal is greater than the positive
threshold. The negative threshold is not
used.
Below –
Signal is less than the negative threshold.
The positive threshold is not used.
Outside
+/-
Signal is less than the negative threshold
or greater than the positive threshold.
Below +
Signal is less than the positive threshold.
The negative threshold is not used.