4-40
MENU DESCRIPTIONS
www.maxcessintl.com
FIFE-500-XL
MI 2-267 1 D
termination enabled.
Note: When assigning network addresses, it is recommended to start drive
addresses at 2 or higher. Leaving address 1 vacant facilitates replacing or
adding a new drive. Since the default drive address is 1, it will initially appear
at this address where it can be easily reassigned.
Press ACCEPT to save changes.
Press CANCEL to exit without saving any changes.
LINE SPEED
This menu is used to calibrate the line speed input signal
and configure the line speed option.
Navigation:
MANUAL
SETUP
Page forward
Page forward
LINE SPEED
Line speed control is used to automatically increase or decrease guide
correction speed according to web travel speed. The guide correction speed
influence applies only in the Automatic mode. The line speed input accepts a
0mA to 20mA signal representing the process line speed.
Maximum Speed bar graph – This bar graph shows the current state of the
calibrated line speed input. The calibrated line speed input signal range is