4-43
MENU DESCRIPTIONS
www.maxcessintl.com
FIFE-500-XL
MI 2-267 1 D
MCP-05
This menu is used to enable and configure the optional MCP-05
sensor positioning option.
Navigation:
MANUAL
SETUP
Page forward
Page forward
MCP-05 OPTION
Enable MCP-05 – MCP-05 seek and manual control options are enabled
when this control is checked.
Show manual controls – Enables the appearance of a new button on the
Operator Level screen that leads directly to the MCP-05 manual control
screen. The MCP-05 manual control button is shown below.
Propagate alarms – Control for the external MCP-05 device consumes two
alarm signals. Enabling this option causes the state of the consumed alarm
signals (selected by Control Sources) to be sent to the MCP-05 alarm
outputs. These signals function normally on the MCP-05 outputs with the
following exceptions:
They are delayed by up to 500mS.
They do not function during MCP-05 manual control or seek
operations. During this time, they maintain their previous state.
Re-seek on ASC – Checking this option will cause the MCP-05 sensor