25
cHAPter 7: troUblesHooting
7.9 troUblesHooting - Motor oVerloAd, oVer cUrrent, or syncHronizAtion errors
Motor oVerloAd, oVer cUrrent, or syncHronizAtion error
Possible cAUses:
1) The unit has incorrect software in the Lower Control Board.
2) The incline motor(s) are damaged.
solUtion:
1) Press and hold both LEVEL keys until Manager appears on the display.
2) Scroll to P10 Software Version using the LEVEL keys and press SELECT.
a. Confirm the LCB software version is S004 or higher, if it S003 or lower, replace the LCB.
3) Open the left and right rear covers (Figures A & B).
4) Scroll to P11 Calibration using the LEVEL keys and press SELECT.
a. Check to see if one or both of the incline motors are slow or not moving. If so, replace the affected incline motor.