40
cHAPter 8: PArt rePlAceMent gUide
1) Turn off the power and disconnect the cord from the machine.
2) Remove the two screws holding the plastic handlebar cover in place and remove the cover (Figure A).
3) Remove the 4 bolts that hold the handlebar to the console mast being careful to support the handlebar (Figures B and C).
4) Carefully remove the wires from inside the console mast until the connectors on the ends come free and disconnect (Figure D).
5) To install a new handlebar assembly, connect the new handlebar and carefully push the heart rate wires into the console mast.
6) Attach the new handlebar assembly to the console mast using the 4 screws removed in Step 3.
7) Reattach the cover over the handlebar assembly.
8) Test the Ascent Trainer for function as outlined in Section 8.20.
figUre A
figUre b
figUre c
figUre d
8.11 HAndlebAr AsseMbly rePlAceMent
Summary of Contents for A3x-01 Ascent Trainer
Page 1: ...A 3 x 0 1 A s c e n t T r a i n e r SER V ICE M A N U A l ...
Page 2: ......
Page 19: ...15 Chapter 7 TROUBLESHOOTING 7 1 Electrical Diagrams ...
Page 20: ...16 7 1 electrical diagrams Chapter 7 TROUBLESHOOTING Wiring Diagram Instructions ...
Page 21: ...17 Chapter 7 TROUBLESHOOTING 7 1 electrical diagrams P05 Console Cable P04 Pulse Sensor Wire ...
Page 22: ...18 7 1 electrical diagrams chapter 7 troubleshooting P02 Elevation Wire P14 ECB Load Wire ...
Page 52: ...48 Chapter 8 Part Replacement Guide 8 17 link arm replacement continued ...
Page 68: ...64 notes ...