StEP 1: CLUB EtHERNEt WIRING (customer responsibility)
ETHERNET WIRING OPTIONS:
Each piece of cardio equipment that will be equipped with a PCTV requires connectivity to the Gateway via Ethernet.
- CAT6 cabling is recommended, CAT5e is acceptable if CAT6 is unavailable.
Cable Wiring Option 1 - Home Runs:
Run cable(s) directly from the patch panel to each touchscreen (and terminate with a coupler). This option is more secure but can be
expensive depending on the size and layout of the club.
Cable Wiring Option 2 - Switches on the Floor:
Cable from the Patch Panels to switch(es) on the floor and from the floor switches to the screens. This is a less expensive option, but leaves
more opportunity for disconnection.
IMPORTANT:
Commercial grade cable management systems should be used to protect all cabling and distribution hubs from foot traffic,
tampering, and accidental disconnects.