![Masimo Pronto Pulse CO-Oximeter Operator'S Manual Download Page 24](http://html1.mh-extra.com/html/masimo/pronto-pulse-co-oximeter/pronto-pulse-co-oximeter_operators-manual_1735228024.webp)
Pronto
Chapter 2: System Description
www.masimo.com
22
Masimo
Ref. Feature
Description
1
Parameter/
Measurement
Numeric Display
Displays parameter/measurement numeric values once a spot check test is
complete.
2 Pulse Indicator
Flashes with patient's pulse reading (PR) during spot check test period.
3 Spot Check
Progress Indicator
Incrementally illuminates upward after a SpHb spot check has been initiated.
This indicates progress towards completion of a SpHb spot check. A fully
illuminated spot check progress indicator indicates a competed spot check.
4
Parameter/
Measurement
Label Display
Displays parameter/measurement label once a spot check test is complete.
5 Power Button
Powers the device on or off. Press the button once to power on. Press and hold
the button for two (2) seconds to power off.
6 Battery Level
Indicator
Battery charge level is indicated by four LED indicators. All four indicators will
be lit when the batteries are full, with fewer indicators being lit as the
batteries lose their charge. For more information, see
Battery Level Indicator
on page 30.
7
Patient Cable /
Sensor Connector
The Patient Cable/Sensor connector is where a compatible sensor is
connected to the device.
8 Low SIQ Indicator This illuminates to indicate low confidence in the measurement displayed.
For more information, see
Low Signal I.Q. (Low SIQ)
on page 40.
9 Sensor Use
Indicator
This illuminates to display the approximate number of uses remaining for the
attached sensor. The bottom LED will turn red when the remaining uses for
the connected sensor are low. The approximate number of sensor uses
remaining is displayed upon power up (if a sensor is attached) and when a
sensor is connected.
10 SpHb Button
Press to initiate total hemoglobin (SpHb) spot check information on display
or to display a total hemoglobin (SpHb) spot check test. When navigating the
device menu, pressing this button will move to the next menu option and will
confirm a setting change. For more information, see
Navigating the Menu
on
page 31.
11 Up/Down Arrow
Buttons
Use the
Up
or
Down
arrow buttons to scroll between parameter or
measurement spot check results. When in the device menu, use the
Up
or
Down
arrow buttons to scroll through menu setting options. For more
information, see
Navigating the Menu
on page 31.
12 Speaker
Provides audible indication of alert conditions, pulse tone, and feedback for
control button presses.