16
Cyclo IP65 Directional user manual
Replacement metal glands must have the following characteristics:
Temperature range: . . . . . . . . . . . . . . . . . . . -20° to +70°C or better
Ingress protection rating: . . . . . . . . . . . . . . . . . . . . . . . IP67 or IP68
Power cable gland thread size: . . . . . . . . . . . . . . . . . . . . . . . . . M25
Data cable gland thread size: . . . . . . . . . . . . . . . . . . . . . . . . . . M16
Minimum entry thread length: . . . . . . . . . . . . . . . . . 10 mm (0.4 in.)
I n s t a l l i n g c a b l e u s i n g r u b b e r m e m b r a n e g l a n d s
DANGER! Using a rubber membrane
gland involves making a hole in the
membrane. A used gland is therefore
only waterproof with cable installed. If
the cable is removed, the hole in the
housing must be sealed with a
blanking plug or new gland.
To install cable using a rubber gland:
1. Push a round spiked object through
the center of the membrane from the
outside of the housing just enough to pierce it. Do not enlarge the hole or
remove rubber from the membrane.
2. Push cable through the gland from the outside of the housing.
I n s t a l l i n g c a b l e u s i n g m e t a l c a b l e g l a n d s
Two sizes of metal cable gland are supplied loose with the product. Use the
larger glands for power cable entry and the smaller glands for DMX data
cable entry.
To install cable using a metal cable gland:
1. Remove a blanking plug that matches the cable gland size from the base
module housing.
Figure 9: Thorsman rubber
membrane cable glands