IOM -  

Horizontal/Side Discharge Condensing Units

3

3

Horizontal/Side Discharge Condensing Units

1) Install according to this installation instructions strictly. If installation is defective, it will cause water

leakage, electrical shock fire, and may void the warranty.

 

 

 

.

2) Use the manufacturer’s specified and supplied parts only

3) Install in a strong and firm location which is able to withstand the unit’s weight. If the strength is

insufficient or installation is not properly done, the units can fall and cause injury.

4) For electrical work, follow all local and National electrical codes  and these installation instructions.

An independent circuit and single outlet must be used. If electrical circuit capacity is not enough or a

 

 

 

 

 

 

   

   

 

 

   

 

 

defect found in electrical work, it may cause electrical shock or fire.

 

   

 

 

 

 

5) Use the specified cable, connect tightly and clamp the cable so that no external force will be acted

on the terminal. If connection is loose, it may cause excessive heat build up.

 

 

   

 

   

 

 

6) Wiring routing must be properly arranged so that control board cover is fixed properly. If control board

cover is not fixed perfectly, it will cause heat build up at connection point of terminal, fire or electrical shock.

     

 

     

 

   

 

   

     

 

7) When carrying out piping connection, take care not to let air substances other than the specified

refrigerant go into refrigeration circuit. Otherwise, it will cause lower capacity, abnormal high pressure

   

 

 

 

   

 

 

 

 

 

 

in the refrigeration cycle, explosion and injury.

 

 

 

 

 

 

8) Do not modify the length of the power supply cord or use an extension cord, and do not share the

single outlet with other electrical appliances. Otherwise, it may cause fire or electrical shock.

 

 

 

 

 

 

 

 

   

 

1) This equipment must be properly grounded and installed with and ground leakage current breaker,

 electrical shock.

otherwise it may cause

2) Do not install the unit in place where leakage of flammable gas may occur. If gas leaks and

accumulates near or surroundings the unit, it may cause fire.

3) Carry out drainage piping as mentioned in installation instructions. If drainage is not properly done,

water may enter the room and damage the furniture.

  The seriousness of safety precautions is classified by the following indications:

This symbol indicates the possibility of death or serious injury.

This symbol indicates the possibility of injury or damage to property.

SAFETY PRECAUTIONS

CAUTION

WARNING

CAUTION

WARNING

      Please read this installation manual completely before installing the product.

      If the power cord is damaged, replacement work shall be performed by authorized personnel only.

      Installation work must be performed in accordance with all local and national codes by authorized 

      personnel only. 

      Contact an authorized service technician for repair, maintenance or installation of this unit.

       

The design and specifications are subject to change without prior notice for product improvement. 

      Consult with the sales agency or manufacturer for details.

All the pictures in the instructions are for explanation purposes only, and may differ from the actual 

      product you purchased.

      

 

Summary of Contents for Comfort-Aire CMA1412SG-0

Page 1: ...17 787 2100 www marsdelivers com Installation Operation and Maintenance Manual Horizontal Side Discharge Condensing Units Models CMA1412SG 0 CMA1418SG 1 CMA1424SG 1 CMA1430SG 1 CMA1436SG 1 CMA1448SG 1...

Page 2: ...ion Operation and Maintenance TABLE OF CONTENTS Safety Precautions 3 General Operating Instructions 4 General Product Information 5 Outdoor Unit Installation 6 7 Unit Wiring 8 12 Wiring Diagrams 8 12...

Page 3: ...efrigeration cycle explosion and injury 8 Do not modify the length of the power supply cord or use an extension cord and do not share the single outlet with other electrical appliances Otherwise it ma...

Page 4: ...imes per hour If you notice more frequent starts call your service contractor 4 For energy conservation reasons you may want to set your thermostat at a higher temperature when you are away Do not rai...

Page 5: ...uctless air handlers may be used but often do not include an expansion device A properly sized thermostatic expansion valve is recommended Consult AHRI s directory of certified products for indoor mat...

Page 6: ...r snow or ice may fall from a roof onto the unit In climates where snow is a consideration locate the unit away from areas prone to drifting Ensure the location of the unit will not be subject to snow...

Page 7: ...e maintained to ensure that the air inlets and outlets are not obstructed See Fig 4 Anchor the outdoor unit with a 10mm 3 8 inch diameter bolt and nut tightly on a concrete or rigid surface See Fig 5...

Page 8: ...ll likely result in failure of the compressor and other electrical components and voids the warranty NOTE The supply voltage must be consistent with the rated voltage of the air conditioner not to exc...

Page 9: ...tinued NOTE1 Please refer to the installation instructions of the 24V thermostat used in conjunction with this unit for additional wiring instructions TERMINAL bLOCk OF OUTDOOR UNIT TERMINAL bLOCk OF...

Page 10: ...Horizontal Side Discharge Condensing Units 10 Horizontal Side Discharge Condensing Units OUTDOOR UNIT WIRING CONNECTION continued 12K 18K NOTE For reference only the actual wiring diagram shall preva...

Page 11: ...IOM Horizontal Side Discharge Condensing Units 11 24K 30K NOTE For reference only the actual wiring diagram shall prevail 36K...

Page 12: ...IOM Horizontal Side Discharge Condensing Units 12 48K Horizontal Side Discharge Condensing Units 12 NOTE For reference only the actual wiring diagram shall prevail...

Page 13: ...added for interconnecting tubing The unit s service valves are shipped in the closed position and should not be opened until final connections and evacuation are completed The recommended procedure fo...

Page 14: ...s a reference to ensure performance 2XWGRRU PELHQW 7HPSHUDWXUH 96 3UHVVXUH 2XWGRRU 7HPSHUDWXUH 1RWH 7 QGRRU 7HPSHUDWXUH 2 7 2XWGRRU 7HPSHUDWXUH 5HPRYH UHIULJHUDQW LI WKH SUHVVXUH LV DERYH WKH FKDUW YD...

Page 15: ...umer The consumer must retain a receipted bill of sale as proof of warranty period Without this proof the express warranty begins on the date of shipment from the factory REMEDY PROVIDED BY THE LIMITE...

Page 16: ...DOOHU LV UHVSRQVLEOH IRU YHULI LQJ GLPHQVLRQDO GDWD RQ WKH DFWXDO SURGXFW SULRU WR EHJLQQLQJ DQ LQVWDOODWLRQ SUHSDUDWLRQV QFHQWLYH DQG UHEDWH SURJUDPV KDYH SUHFLVH UHTXLUHPHQWV DV WR SURGXFW SHUIRUPDQ...

Reviews: