Installation manual - Ecotype - 31
3.8 Electrical wiring for Ecotype Covering System
The application of the motorised covering system requires the installation of an elementary wiring, suitable for supplying
electricity and the proper functioning of the covering.
The system equipment includes, apart from the above-described motor, following material:
1. Control Box
→
see paragraph 3.8.1
2.
Radio remote control “TX MARCOLIN”
3. Set of electrical contacts
4. Electrical wiring
identification plate: inside the door
→
The electrical system also includes the connection cables for the various components.
Each supplied cable has been prepared and adapted for a specific application. Therefore, each one is marked with a special
initial.
The table below shows characteristics, application and identification marking of the several connection cables.
Length
Cable End 1
Reference Colour
Cable End 2
Application
4.50 m
Open ended for
cutting to length to
connect to battery
A
80 A female plug
Connection from the tractor
battery to the semi-trailer
connection zone
2.50 m
80 A male plug
B
Open ended for
cutting to length to
connect to Control
Box (1- 2)
Connection from the semi-trailer
connection zone to the Control
Box power supply
2.50 m
Connection to
Control Box
terminals
(3 - 4)
C
Open ended for
cutting to length to
connect to contact
plate
Connection from Control Box
(motor output) to contact plate
4.50 m
Connection to
contact plate
terminals
D
Open ended for
cutting to length,
for connection to
the motor
Connection from contact plate to
motor
WARNING!
Prior to establish the electrical connections “disconnect the battery”.
The wiring system must be performed by qualified personnel in strict accordance with the instructions
described in this manual and the wiring diagram shown in paragraph 6.1.
Note:
If use of different cables than those supplied should be necessary, consult previously the manufacturer.