Important: always unplug before cleaning.
When using the appliance for the first time, clean the tank, the blade and the auger with a dry
kitchen towel. Clean the other parts of the appliance (dies and attachments) passing a small quantity
of pasta and then discard it.
To remove the auger: after unscrewing the closing ring, remove the die and push the auger from
inside the tank as shown in figure A. After separating the auger from the blade, pull it from outside
as shown in figure B.
To remove the blade: push it towards the hole on the left as shown in figure C and lift the right part
of the blade (figure D) to take it out of the tank. To insert the blade: repeat the operation backwards.
2 - PREPARING THE MACHINE FOR USE
A
C
D
B
26
27
To insert the auger: thread the hexagonal hole (figure E) of the auger on the blade’s shaft. Rotate
the auger until the 2 red dots correspond (figure F) and push until it touches the blade (figure G).
Keep the die leaned to the extrusion space as shown in figure H (the two parts of composed dies
must be tightly closed) and screw the closing ring tight using the key provided.
2 - PREPARING THE MACHINE FOR USE
E
F
G
H