Oven insulation material
must be 1.2”
(30mm
–
3cm) to combustible material from all sid
es, and 14” (356mm
–
35,6 cm) clearance to combustibles from the top of oven insulation material. Area above the oven doorway
and 6” (152mm) to each side of the doorway must be covered with non
-combustible material.
Oven insulation material
KEEP THE APPLIANCE AREA FREE AND CLEAR FROM COMBUSTIBLES
OVEN FLUE VENTING MEASURES
Oven Model
Flue collar diam
inch measure
Flue collar diam
millimeter measure
MF110*
8”
200 mm
MF130*
8”
200 mm
MF150*
8”
200 mm
*All models, series
COMBUSTIBLE MATERIAL
14
”
(356 mm - 35 cm) top clearance
from oven insulation material to
combustible building
1,2
”
(30mm - 3 cm) sides clearance
from oven insulation material to
combustible building